Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Wien Klin Wochenschr ; 133(23-24): 1272-1280, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34698961

RESUMEN

BACKGROUND: Seroepidemiological studies provide important insight into the spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV­2) in our society. We aimed to determine seropositivity of SARS-CoV­2 antibodies and its cross-sectional correlates in a large cohort of blood donors. METHODS: In this observational cohort study, we tested healthy blood donors residing in Tyrol, Austria, for SARS-CoV­2 antibodies using the Abbott SARS-CoV­2 IgG chemiluminescent microparticle immunoassay. We estimated 95% confidence intervals (95% CI) of seroprevalences using bootstrapping and tested for differences by participant characteristics using logistic regression. FINDINGS: Between 8 June and 4 September 2020, we screened 5345 healthy individuals at local blood donor sessions (mean age 42.7 years, SD 13.5 years, 46.7% female). Overall seroprevalence was 3.1% (95% CI 2.7-3.6%, 165 cases), which is 5.1-fold higher (95% CI 4.5-6.0%) than the case number identified by the health authorities in the state-wide testing program (0.6%; 4536 out of 757,634). Seroprevalence was higher in the district Landeck (16.6%, P < 0.001) and in individuals aged < 25 years (4.7%, P = 0.043), but did not differ by gender, blood types, or medication intake. The odds ratio for seropositivity was 2.51 for participants who had travelled to Ischgl (1.49-4.21, P = 0.001), 1.39 who had travelled to other federal states (1.00-1.93, P = 0.052), and 2.41 who had travelled abroad (1.61-3.63, P < 0.001). Compared to participants who had a suspected/confirmed SARS-CoV­2 infection but were seronegative, seropositive participants more frequently reported loss of smell (odds ratio = 2.49, 1.32-4.68, P = 0.005) and taste (odds ratio = 2.76, 1.54-4.92, P = 0.001). CONCLUSION: In summer 2020, SARS-CoV­2 seroprevalence in Tyrolean blood donors was 3.1%. Our study revealed regional variation and associations with young age, travel history and specific symptoms.


Asunto(s)
Donantes de Sangre , COVID-19 , Adulto , Anticuerpos Antivirales , Austria/epidemiología , Estudios Transversales , Femenino , Humanos , Masculino , Prevalencia , SARS-CoV-2 , Estudios Seroepidemiológicos
2.
Infect Dis Ther ; 10(4): 2381-2397, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34368915

RESUMEN

INTRODUCTION: We performed a multicentre evaluation of the Elecsys® Anti-SARS-CoV-2 immunoassay (Roche Diagnostics), an assay utilising a recombinant protein representing the nucleocapsid (N) antigen, for the in vitro qualitative detection of antibodies to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). METHODS: Specificity was evaluated using serum/plasma samples from blood donors and routine diagnostic specimens collected before September 2019 (i.e., presumed negative for SARS-CoV-2-specific antibodies); sensitivity was evaluated using samples from patients with polymerase chain reaction (PCR)-confirmed SARS-CoV-2 infection. Point estimates and 95% confidence intervals (CIs) were calculated. Method comparison was performed versus commercially available assays. RESULTS: Overall specificity for the Elecsys Anti-SARS-CoV-2 immunoassay (n = 9575) was 99.85% (95% CI 99.75-99.92): blood donors (n = 6714; 99.82%), routine diagnostic specimens (n = 2861; 99.93%), pregnant women (n = 2256; 99.91%), paediatric samples (n = 205; 100.00%). The Elecsys Anti-SARS-CoV-2 immunoassay demonstrated significantly higher specificity versus LIAISON SARS-CoV-2 S1/S2 IgG (99.71% vs. 98.48%), EUROIMMUN Anti-SARS-CoV-2 IgG (100.00% vs. 94.87%), ADVIA Centaur SARS-CoV-2 Total (100.00% vs. 87.32%) and iFlash SARS-CoV-2 IgM (100.00% vs. 99.58%) assays, and comparable specificity to ARCHITECT SARS-CoV-2 IgG (99.75% vs. 99.65%) and iFlash SARS-CoV-2 IgG (100.00% vs. 100.00%) assays. Overall sensitivity for Elecsys Anti-SARS-CoV-2 immunoassay samples drawn at least 14 days post-PCR confirmation (n = 219) was 93.61% (95% CI 89.51-96.46). No statistically significant differences in sensitivity were observed between the Elecsys Anti-SARS-CoV-2 immunoassay versus EUROIMMUN Anti-SARS-CoV-2 IgG (90.32% vs. 95.16%) and ARCHITECT SARS-CoV-2 IgG (84.81% vs. 87.34%) assays. The Elecsys Anti-SARS-CoV-2 immunoassay showed significantly lower sensitivity versus ADVIA Centaur SARS-CoV-2 Total (85.19% vs. 95.06%) and iFlash SARS-CoV-2 IgG (86.25% vs. 93.75%) assays, but significantly higher sensitivity versus the iFlash SARS-CoV-2 IgM assay (86.25% vs. 33.75%). CONCLUSION: The Elecsys Anti-SARS-CoV-2 immunoassay demonstrated very high specificity and high sensitivity in samples collected at least 14 days post-PCR confirmation of SARS-CoV-2 infection, supporting its use to aid in determination of previous exposure to SARS-CoV-2.

3.
J Clin Microbiol ; 55(7): 2180-2187, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28468860

RESUMEN

Screening of blood for human T-cell lymphotropic virus type 1 and type 2 (HTLV-1 and -2, respectively) is important to diagnose and prevent infection and ensure the safety of blood supplies. The Elecsys HTLV-I/II assay is a newly developed, electrochemiluminescence screening assay for the detection of HTLV-1/2 infection. The sensitivity and specificity of the Elecsys HTLV-I/II assay were determined using well-characterized HTLV-1/2-positive serum and plasma samples and routine diagnostic and blood donor samples expected to be HTLV negative, respectively. These results were compared with those for at least one of the following CE-marked assays at seven independent laboratories and the Roche Diagnostics facility in Penzberg, Germany: Abbott Architect rHTLV-I/II, Ortho Avioq HTLV-I/II Microelisa system, Abbott Prism HTLV-I/HTLV-II, and DiaSorin Murex HTLV I+II. Fujirebio INNO-LIA HTLV-I/II Score was used as a confirmatory assay. The Elecsys HTLV-I/II, Abbott Architect rHTLV-I/II, and Abbott Prism HTLV-I/HTLV-II assays detected all HTLV-1/2-positive samples (sensitivity, 100%). Sensitivity for Ortho Avioq HTLV-I/II was 98.63%. The Elecsys HTLV-I/II assay had a specificity of 99.95% in blood donor samples, which was comparable to results for the other assays (range, 99.91 to 100%). In routine diagnostic samples, the specificity of the Elecsys HTLV-I/II assay was 99.83%, compared with 99.70% for Abbott Architect rHTLV-I/II. Specificity for the Elecsys HTLV-I/II assay in potentially cross-reactive samples was 100%, compared with 99.0% for Ortho Avioq HTLV-I/II and 99.2% for DiaSorin Murex HTLV I+II. The Elecsys HTLV-I/II assay has the sensitivity and specificity to support its use as a routine screening assay for detecting HTLV infection.


Asunto(s)
Sangre/virología , Infecciones por HTLV-I/diagnóstico , Infecciones por HTLV-II/diagnóstico , Virus Linfotrópico T Tipo 1 Humano/aislamiento & purificación , Virus Linfotrópico T Tipo 2 Humano/aislamiento & purificación , Tamizaje Masivo/métodos , Europa (Continente) , Humanos , Japón , Mediciones Luminiscentes/métodos , Sensibilidad y Especificidad
4.
Arch Dis Child ; 102(7): 603-606, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28039141

RESUMEN

OBJECTIVES: Due to a high linkage disequilibrium of diabetes and coeliac-specific human leucocyte antigen (HLA) genotypes, the prevalence of coeliac disease (CD) in children and adolescents with diabetes mellitus type 1 (T1D) is much higher than in the general population. Recently, the European Society for Paediatric Gastroenterology, Hepatology and Nutrition (ESPGHAN) revised new screening guidelines in which genotyping for coeliac-specific HLA alleles is recommended for high-risk patients as patients with T1D. The aim of our study was to investigate the frequency and distribution of coeliac-specific HLA genotypes in paediatric patients with T1D. STUDY DESIGN: HLA genotyping was performed on paediatric patients with T1D, recruited at the Medical University Hospital of Innsbruck and Graz. The test was done by PCR. Statistical analysis was performed with IBM-SPSS V.20. RESULTS: In 121 paediatric patients with T1D (52% male), mean age 13.3 (SD 3.9) years, mean age at diabetes diagnosis 7.4 (SD 3.8) and mean diabetes duration of 5.9 (SD 3.3) years, HLA genotyping was conducted. Ninety-two per cent showed positive HLA DQ2 and/or HLA DQ8 genotypes. Thirty-four per cent carried HLA DQ2, 33% were HLA DQ2+DQ8 positive and 25% of the patients showed positive results for HLA DQ8 alone. Only 8% had no coeliac-specific HLA markers. Four (3%) patients were diagnosed with CD. CONCLUSIONS: The majority of paediatric patients with T1D has positive coeliac-specific HLA genotypes DQ2 and/or DQ8. Therefore, genotyping for coeliac-specific HLA alleles as a first-line test in patients with T1D as recommended in the ESPGHAN guidelines does not seem reasonable. Screening for coeliac-specific antibodies needs to be performed on a regular basis for patients with T1D.


Asunto(s)
Enfermedad Celíaca/genética , Diabetes Mellitus Tipo 1/genética , Antígenos HLA-DQ/genética , Adolescente , Austria , Enfermedad Celíaca/diagnóstico , Niño , Preescolar , Diagnóstico Precoz , Emigrantes e Inmigrantes , Femenino , Genotipo , Técnicas de Genotipaje , Humanos , Masculino , Factores de Riesgo , Adulto Joven
6.
Clin Vaccine Immunol ; 22(1): 17-26, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25355799

RESUMEN

Syphilis is a health problem of increasing incidence in recent years that may have severe complications if not diagnosed and treated at an early stage. There are many diagnostic tests available for syphilis, but there is no gold standard, and diagnosis therefore usually relies upon a combination of tests. In this multicenter study, we evaluated the treponemal Elecsys syphilis assay for use in the diagnosis of syphilis in routine samples, i.e., when syphilis is suspected or during antenatal or blood donation screening. The sensitivity and specificity of the Elecsys syphilis assay were compared head to head with those of other treponemal assays used in routine clinical practice and were assessed in potentially cross-reactive samples from patients with Epstein-Barr virus, HIV, and Lyme disease. In a total of 8,063 syphilis-negative samples collected from routine diagnostic requests and blood donations, the Elecsys syphilis assay had a specificity of 99.88%. In 928 samples previously identified as syphilis positive, the sensitivity was 99.57 to 100% (the result is presented as a range depending on whether four initially indeterminate samples are included in the assessment). The specificity of the Elecsys syphilis assay in patients with other infections was 100%; no false-positive samples were identified.


Asunto(s)
Anticuerpos Antibacterianos/sangre , Pruebas Diagnósticas de Rutina/métodos , Sífilis/diagnóstico , Treponema pallidum/inmunología , Humanos , Inmunoensayo/métodos , Juego de Reactivos para Diagnóstico , Sensibilidad y Especificidad , Sífilis/inmunología
7.
J Med Virol ; 85(8): 1362-8, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23765774

RESUMEN

Routine screening of patients at risk of hepatitis C virus (HCV) infection has become a priority given recent improvements in therapeutic options and the asymptomatic nature of most chronic infections. The aim of this study was to evaluate the performance of the Elecsys® Anti-HCV II assay, a new qualitative antibody immunoassay, compared with currently available assays, and assess its suitability for routine diagnostic testing. The sensitivity of the Elecsys® Anti-HCV II, ARCHITECT® Anti-HCV, AxSYM® HCV 3.0, PRISM® HCV, Vitros® ECi Anti-HCV, Elecsys® Anti-HCV, and ADVIA Centaur® HCV assays was compared using commercially available seroconversion panels and samples from patients known to be HCV positive and infected with HCV genotypes 1-6. Specificity was investigated using samples from blood donors, unselected hospitalized patients, and patients with potential cross-reacting factors or from high-risk groups. The Elecsys® Anti-HCV II assay detected more positive bleeds than the comparator assays, was more sensitive in recognizing early HCV infection, and correctly identified all 765 samples known to be HCV positive, regardless of genotype. The overall specificity of the Elecsys(®) Anti-HCV II assay was 99.84% (n=6,850) using blood donor samples, 99.66% (n=3,922) using samples from unselected hospitalized patients, and 99.66% (n=2,397) using samples from patients with potentially cross-reacting factors or from high-risk groups. The specificity of the Elecsys® Anti-HCV II assay was superior or equal to the comparator assays. In conclusion, the Elecsys® Anti-HCV II assay is a sensitive and specific assay suitable for routine use in the reliable detection of anti-HCV antibodies.


Asunto(s)
Técnicas de Laboratorio Clínico/métodos , Hepacivirus/inmunología , Anticuerpos contra la Hepatitis C/sangre , Hepatitis C/diagnóstico , Femenino , Humanos , Inmunoensayo/métodos , Masculino , Embarazo , Sensibilidad y Especificidad
8.
J Allergy Clin Immunol ; 130(6): 1368-74.e2, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23063584

RESUMEN

BACKGROUND: Control of HIV is suggested to depend on potent effector functions of the virus-specific CD8(+) T-cell response. Antigen opsonization can modulate the capture of antigen, its presentation, and the priming of specific CD8(+) T-cell responses. OBJECTIVE: We have previously shown that opsonization of retroviruses acts as an endogenous adjuvant for dendritic cell (DC)-mediated induction of specific cytotoxic T lymphocytes (CTLs). However, in some HIV-positive subjects, high levels of antibodies and low levels of complement fragments coat the HIV surface. METHODS: Therefore we analyzed the effect of IgG opsonization on the antigen-presenting capacity of DCs by using CD8(+) T-cell proliferation assays after repeated prime boosting, by measuring the antiviral activity against HIV-infected autologous CD4(+) T cells, and by determining IFN-γ secretion from HIV-specific CTL clones. RESULTS: We find that DCs exposed to IgG-opsonized HIV significantly decreased the HIV-specific CD8(+) T-cell response compared with the earlier described efficient CD8(+) T-cell activation induced by DCs loaded with complement-opsonized HIV. DCs exposed to HIV bearing high surface IgG levels after incubation in plasma from HIV-infected subjects acted as weak stimulators for HIV-specific CTL clones. In contrast, HIV opsonized with plasma from patients exhibiting high complement and low IgG deposition on the viral surface favored significantly higher activation of HIV-specific CD8(+) T-cell clones. CONCLUSION: Our ex vivo and in vitro observations provide the first evidence that IgG opsonization of HIV is associated with a decreased CTL-stimulatory capacity of DCs.


Asunto(s)
Células Dendríticas/inmunología , Infecciones por VIH/inmunología , VIH/inmunología , Linfocitos T Citotóxicos/inmunología , Anticuerpos Antivirales/inmunología , Presentación de Antígeno , Antígenos Virales/inmunología , Linfocitos T CD4-Positivos/inmunología , Proliferación Celular , Células Clonales , Proteínas del Sistema Complemento/inmunología , Humanos , Interferón gamma/inmunología , Activación de Linfocitos
9.
Transfusion ; 47(4): 703-14, 2007 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-17381630

RESUMEN

BACKGROUND: Besides ABO and RH, the KEL blood group system, including the two antithetical antigens KEL1 and KEL2, is the most important owing to the frequent appearance of anti-KEL alloantibodies and their considerable clinical significance. So far, only limited information was available on KEL variant alleles determining the rare silent KELnull and KELel phenotypes with absent or diminished KEL antigen expression detected only by adsorption-elution techniques, respectively. STUDY DESIGN AND METHODS: For a systematic investigation of the KELnull and KELel phenotypes, 401 KEL:1,-2 samples (representing 2.6% of all Austrian KEL:1,-2 samples) and 811 KEL:1,2 samples were genotyped for the KEL*1/KEL*2-specific single-nucleotide polymorphism. All heterozygous KEL*1/KEL*2 and 4 additional KELnull samples were subjected to detailed immunohematologic examination and allele-specific sequencing. RESULTS: In 14 KEL:1,-2 samples, discrepant KEL*1/KEL*2 heterozygosity was observed, indicating the presence of silent or barely expressed KEL*2 alleles, whereas all KEL:1,2 individuals were homozygous for KEL*2. In the course of further molecular analysis, 8 novel KEL*2null and 2 KEL*2el alleles were discovered, representing 67 and 33 percent of previously known KEL*2null- and KEL*2el-encoding alleles, respectively. In addition, two different known KEL*2null and KEL*2el alleles each were confirmed. The immunohematologic properties of KEL variant red blood cells were defined by extended KEL phenotyping and flow cytometric KEL1, KEL2, KEL4, and KEL7 antigen as well as total Kell protein quantification. CONCLUSION: For the first time, exact KELnull and KELel population frequencies could be established in this population.


Asunto(s)
Alelos , Variación Genética , Sistema del Grupo Sanguíneo de Kell/genética , Secuencia de Aminoácidos , Austria , Secuencia de Bases , Donantes de Sangre , Análisis Mutacional de ADN , Eritrocitos/inmunología , Eritrocitos/metabolismo , Citometría de Flujo , Frecuencia de los Genes , Heterogeneidad Genética , Genotipo , Geografía , Humanos , Sistema del Grupo Sanguíneo de Kell/inmunología , Datos de Secuencia Molecular , Fenotipo , Mutación Puntual , Reacción en Cadena de la Polimerasa , Polimorfismo Genético
10.
J Clin Virol ; 32(1): 67-70, 2005 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-15572009

RESUMEN

The issue of HBV DNA screening on blood donations is controversially discussed since the economic impact of post-transfusion hepatitis B is expected to be relatively low. We report on a case of HBsAg negative unapparent acute HBV infection, which was detected by HBV NAT testing on 96-member maxi-pools with a commercially available NAT assay, which has a detection threshold of 3 IU/mL of plasma. The presence of an HBsAg escape mutant could be excluded by sequencing the amplified DNA. Follow-up testing showed the presence of an acute HBV infection (anti-HBc-IgM positive) and finally anti-HBs seroconversion. Although the reduction of the diagnostic window with NAT screening on maxi-pools may be relatively low, it may help to improve the residual risk of blood donation, especially in asymptomatic HBV infection, where the HBsAg positive period may be very short and low levels of circulating surface antigen are present. It would also permit to detect occult HBV infection in chronic carriers who are HBsAg negative. Since the viral load in chronic isolated anti-HBc positive carriers is low, there is a potential risk for failure of HBV DNA detection with pool-PCR in blood donors. Anti-HBc screening would reduce the residual risk.


Asunto(s)
Donantes de Sangre , Transfusión Sanguínea/normas , Antígenos de Superficie de la Hepatitis B/análisis , Virus de la Hepatitis B/aislamiento & purificación , Hepatitis B/diagnóstico , Técnicas de Amplificación de Ácido Nucleico/normas , Viremia/diagnóstico , Hepatitis B/sangre , Anticuerpos contra la Hepatitis B/sangre , Virus de la Hepatitis B/genética , Humanos , Pruebas Serológicas , Reacción a la Transfusión , Viremia/sangre
11.
J Clin Microbiol ; 40(6): 1938-46, 2002 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-12037046

RESUMEN

Fourth-generation assays for the simultaneous detection of human immunodeficiency virus (HIV) antigen and antibody that were available on the international market until now have antigen detection modules with relatively poor sensitivity and produce a higher rate of false-positive results than third-generation enzyme immunoassays (EIAs). The new Cobas Core HIV Combi EIA with an improved sensitivity for HIV p24 antigen was compared to alternative fourth- and third-generation assays, the p24 antigen test, and HIV type 1 (HIV-1) RNA reverse transcriptase PCR (RT-PCR). A total of 94 seroconversion panels (n = 709 sera), samples from the acute phase of infection after seroconversion (n = 32), anti-HIV-1-positive specimens (n = 730) from patients in different stages of the disease, 462 subtyped samples from different geographical locations, anti-HIV-2-positive sera (n = 302), dilutions of cell culture supernatants (n = 62) from cells infected with different HIV-1 subtypes, selected performance panels from Boston Biomedica Inc., 7,579 unselected samples from blood donors, 303 unselected daily routine samples, 997 specimens from hospitalized patients, and potentially interfering samples (n = 1,222) were tested with Cobas Core HIV Combi EIA. The new assay showed a sensitivity comparable to that of the Abbott HIV-1 AG Monoclonal A for early detection of HIV infection in seroconversion panels. The mean time delay of Cobas Core HIV Combi EIA (last negative sample plus 1 day) in comparison to that for HIV-1 RT-PCR for 87 panels tested with both methods was 2.75 days. The diagnostic window was reduced with Cobas Core HIV Combi EIA by between 3.6 and 5.7 days from that for third-generation assays. The specificities of Cobas Core HIV Combi EIA in blood donors were 99.84 and 99.85% (after repeated testing). Overall, 30 repeatedly reactive false-positive results out of 10,031 HIV-negative samples were obtained with Cobas Core HIV Combi EIA. Our results show that a fourth-generation assay with improved specificity such as Cobas Core HIV Combi EIA is suitable for blood donor screening because of its low number of false positives and because it detects HIV p24 antigen with a sensitivity comparable to that of single-antigen assays.


Asunto(s)
Serodiagnóstico del SIDA , Antígenos VIH/sangre , Proteína p24 del Núcleo del VIH/sangre , Infecciones por VIH/diagnóstico , Técnicas para Inmunoenzimas , Donantes de Sangre , Anticuerpos Anti-VIH/sangre , VIH-1/aislamiento & purificación , VIH-2/aislamiento & purificación , Humanos , Tamizaje Masivo , ARN Viral/sangre , Juego de Reactivos para Diagnóstico , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Sensibilidad y Especificidad , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...